Volume 9, Issue 1 (Semi-Annual 2024)                   CIAUJ 2024, 9(1): 1-16 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nami S, Harutyunyan E, Amer S, Navadad V. Seismic Assessment and Effectiveness of Structural Retrofitting Techniques :A Case Study of Industrial Chimney at Khosravi Leather Factory in Tabriz. CIAUJ 2024; 9 (1) :1-16
URL: http://ciauj-tabriziau.ir/article-1-526-en.html
1- Faculty of Architecture and Urbanism, Tabriz Islamic Art University , s.nami@tabriziau.ac.ir
2- Faculty of Architecture, National University of Architecture and Construction of Armenia, Armenia
3- Faculty of Architecture and Urbanism, Tabriz Islamic Art University, Tabriz, Iran
4- Department of Civil Engineering, Marand Branch, Islamic Azad University, Marand, Iran
Abstract:   (768 Views)
The Khosravi Leather Factory in Tabriz holds significant historical importance as a representative of Iran's early industrial era. This study focuses on the dynamic behavior of the industrial chimney within the factory complex, which is a tall and slender structure vulnerable to seismic forces. In this article, the previously implemented seismic retrofitting techniques, which involved the installation of metal rings around the chimneys, is thoroughly examined. Given the unique challenges posed by these structures, this research investigates the effectiveness of this retrofitting technique through experimental modal analysis and numerical modeling, followed by pushover analysis to evaluate the seismic behavior before and after retrofitting. Based on the test results and observed frequency changes and pushover analysis results, it is evident that this retrofitting technique did not achieve the desired improvement in structural performance.
Full-Text [PDF 3217 kb]   (251 Downloads)    
Type of Study: Case study | Subject: Conceptualization of theorizing in Islamic architecture and urban ism
Received: 2023/12/30 | Accepted: 2024/06/11 | ePublished: 2024/06/29

References
1. Corte G. D, Fiorino, L. Mazzolani, F. M. (2008). Lateral-Loading Tests on a Real RC Building Including Masonry Infill Panels with and without FRP Strengthening, Materials in Civil Engineering, 20(6): 419-431 [DOI:10.1061/(ASCE)0899-1561(2008)20:6(419)]
2. Gentile, C. Saisi, A. Cabboi, A. (2012). Dynamic monitoring of a masonry tower. Proc. of the Int. Conf. SAHC 2012.
3. Ghalishooyan, M., & Shooshtari, A. (2015). Operational modal analysis techniques and their theoretical and practical aspects: A comprehensive review and introduction, 6th International Operational Modal Analysis Conference.
4. Karaca, Z. Türkeli, E. Günaydın, M. Adanur, S. (2015). Dynamic responses of industrial reinforced concrete chimneys strengthened with fiber-reinforced polymers, The structural design of tall and special buildings, 24: 228-241 [DOI:10.1002/tal.1163]
5. Nami, S., & Akhoundi, F. (2022). Understanding the Dynamic Characteristics of Industrial Masonry Chimney for Investigative Preservation: A Case Study of Khosravi Leather Factory Chimney, Iranian and Islamic Architectural and Restoration Research Journal; 5 (14):1-9. [In Persian]
6. Noortman, F.J. (2019). Applicability of the pushover method for the seismic assessment of URM structures in Groningen, Master thesis, TU Delft university.
7. Pallare's ,F.J. Ivorra, S. Pallare's ,L. Adam Jose M. (2009). Seismic assessment of a CFRP-strengthened masonry chimney, Structures and Buildings, 162: 291-299.
8. Rainieri, C. Fabbrocino, G. (2011). Operational modal analysis for the characterization of heritage structures, GEOFIZIKA, 28: 109-125.
9. Salehi, M. Orak, M. Qurbani, M. Ahmadi Bolotaki, M. (2018). Experimental study of the performance of different environmental modal analysis methods with simultaneous random and harmonic excitation, Iranian Mechanical Engineering Research Journal, 20 (2):54-71.
10. Viskovic, A. Antonelli, L. Morgante, F.(2019). Annular Post-Compression by FRP inside Mortar Joints and Vertical Post-Compression by Stainless Steel, for Seismic and Wind Retrofitting of Historical Masonry Chimney, Key Engineering Materials, 817:642-649. [DOI:10.4028/www.scientific.net/KEM.817.642]

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Culture of Islamic Architecture and Urbanism Journal

Designed & Developed by : Yektaweb